Battery Depletion Over Time
Daily Energy Breakdown
Assumptions & Data Sources
Datasheets
- nRF5340 PS v2.0 — MCU + BLE, deep-sleep ~5 uA, BLE TX 3.4 mA
- nRF7002 PS v1.2 — Wi-Fi 6 companion, ~60 mA active, 15 uA shutdown
- nPM1100 PS v1.4 — PMIC, 700 nA quiescent (negligible)
- VL53L4CD DS rev.8 — ToF sensor, 23 mA active, 55 uA ULP per sensor
Efficiency Factors
- AAA efficiency: 70% — pulse-load ~78% × buck-boost regulator ~87% × temp/aging/cutoff ~94%
- Li-ion efficiency: 80% — regulator ~90% × aging/cycle ~92% × temperature ~95% × cutoff reserve ~94%
- Usable mAh = (nominal Wh × efficiency × 1000) / 3.3 V rail
Board-Level Estimates
- Board deep-sleep: 30 uA practical — nRF5340 ~5 uA + nRF7002 shutdown ~15 uA + PCB leakage
- BLE TX to e-ink: 4 mA avg — includes RX windows + BLE stack overhead
- BLE advertising: ~10 uA avg @ 1s interval — always on for e-ink + phone connectivity
- Li-ion protection IC: ~6 uA — overcurrent/undervoltage protection leakage
- Sensor on-time per cycle: 1.0 s — 4 sensors measured sequentially
- Battery self-discharge: ~0.3%/mo Li-ion, ~0.2%/mo AAA — not in formula, adds ~2-5% over product life
- Nordic DevZone #112208 — community power measurement reference
Design Targets
- 9-month threshold = acceptable charge/swap cycle for Podsque v1
- BLE session duration: 3.0 s per e-ink update
- Wi-Fi session default: 8 s (boot + scan + TX + shutdown)